When quality and cost is your target,
Test for the following Drugs of Abuse:
Amphetamine
Barbiturates
Benzodiazepines
Cocaine
Marijuana (THC)
Methamphetamine
Methadone
Opiates
Oxycodone
PCP
| CUT OFF LEVELS | |
| Amphetamine (AMP) | 1000 ng/ml |
| Barbiturates (BAR) | 300 ng/ml |
| Benzodiazepine (BZO) | 300 ng/ml |
| Cocaine (COC) | 300 ng/ml |
| Marijuana (THC) | 50 ng/ml |
| Methadone | 300 ng/ml |
| Methamphetamine (MET) | 500 ng/ml |
| Opiates (OPI) | 300 ng/ml |
| Oxycodone (OXY) | 100 ng/ml |
| Phencyclidine (PCP) | 25 ng/ml |
| THE PROCEDURE | |
| Slide protective sleeve up and dip device into sample up to tips of arrows for ten seconds. | ![]() |
| Slide protective sleeve down. When control band forms results are ready and stable up to one hour. | ![]() |
| Results
Interpretation: Control (C) band must be visible for valid test. - The test is positve if no test band is present. - The test is negative if test band is present. |
![]() |